top of page

NOW IN STOCK... Our 2nd Edition Refrigerant Charging and Service Procedures for Air Conditioning. New procedures, new tools and updated refrigerants...

 

We are EXCITED to announce our new 2nd Edition of the Refrigerant Charging and Service Procedures for Air Conditioning paperback book is now in stock. This book has 450 images on 344 pages! It includes over a hundred more pages and double the amount of images to cover:

  • A2L Refrigerant Changes

  • R-32 and R-454B

  • R-410A and R-22

  • More Step-by-Step Procedures

  • Wireless Probes, Gauge Stubs, Tees

  • All-In-One Digital Manifold Set use

  • Compound Manifold Gauge Sets

  • More Images and Procedures

  • Charging and Recovery with Manifolds

  • Charging and Recovery with Tees and Probes

  • Detailed Troubleshooting Scenarios

  • More Methods to Determine Problems

  • More Airflow Testing Procedures

 

    This book is dedicated to those who are eager to learn the HVAC trade and refrigerant charging/troubleshooting practices. This book contains step by step procedures that include preparing air conditioning and heat pump systems for refrigerant, measuring system refrigerant charges, and troubleshooting systems by measuring refrigerant charge indicators, air temperature measurements, and airflow. Manifold gauge sets, digital manifold sets, digital gauge stubs, and wireless probes are discussed and utilized in examples. This book differs from others in that it provides key insights into each procedure along with tool usage from a technician’s perspective, in language that is easy to understand.     

 

    Concepts are examined such as refrigerant properties, the refrigeration cycle of an air conditioner and heat pump, energy transfer, airflow requirements, components within systems, and common problems.

 

Thank you as always for your support of AC Service Tech!!!

 

NEW-2nd Edition- Refrigerant Charging & Service Procedures for Air Conditioning

SKU: 2PRCSP124
$99.99Price
Quantity
  • 979-8-9889892-1-9

Join Our Updates List!

AC Service Tech HVAC Training is made possible by continued support from our visitors, customers, and support from these Sponsors!

NAVAC LOGO Black_edited.png
Accutrak Logo
TruTech-Tools-Logo-Main (3)[528].png
HavenRGB-FC w_grey horz.png

AC SERVICE TECH, LLC

Updates List

Thanks for submitting!

Thanks for all your continued support! I appreciate all the comments, questions, and responses that I receive from each of you. I look forward to responding to many more! If you have an HVACR related question, drop it in the comment section of one of the YouTube videos at the AC Service Tech YouTube Channel and I will do my best to respond.

 

For business related inquires email us at info@acservicetech.com

Check back regularly as we are always updating and improving this website!

© 2025 AC Service Tech, LLC.

bottom of page